Bookmark and Share

Oracle Error :: SP2-1503

Unable to initialize Oracle call interface

Cause

Indicates a library used by SQL*Plus to communicate with the database failed to initialize correctly.

Action

Check that the Oracle environment or registry entries are consistent and correct. If using the SQL*Plus Instant Client make sure the SQL*Plus and Oracle libraries are from the same release. Make sure you have read access to the libraries.

More Info >>>

Comments (Add Comment)

13/01/2010 12:33:48 by Nilofer

Check if the user running the command has Administrative access. If running on Vista, select the .exe and use "Run as Administrator" option

20/01/2010 02:13:43 by Varun

Great Help Nilofer.. Thanks.. It worked !!

09/02/2010 04:14:27 by Satish

Thanks again Nilofar, it worked for me too. I have Windows 7

10/02/2010 09:05:01 by fantasticvibs

Thx a ton Nilofer... worked for me too... was about to reinstall oracle.

04/05/2010 20:11:06 by Joumdanisatioo

Thanks, Would you please tell me the steps I have to do to solve this problem, I'm using Windows 7

27/07/2010 20:38:59 by Sandeep

Thanks It works. Had similar problem with PL SQL developer